ALTERNATORS
08
AAG compact
AAG
compact
Main technical data
Type
AAG
Rated Voltage (V)
14
28
Rated Current (A)
45 - 75
30 - 40
Stator Diameter (mm)
108
Cooling
Air cooling / Two internal fans (CW or CCW)
Weight
1
(
kg)
~3.5
Max Permanent / Short time
Rotational Speed (RPM)
13.000 / 15.000
Voltage Regulator
Mono-Function (14V / 28V) / Multi-Function (14V)
Power diodes Type
Press-fit Zener (35A (14V) / 50A (28V))
Over-voltage Protection
YES
Zener Voltage (V)
19-25 (14
V) / 34-40 (28V)
Electrical terminalsMono/
Multi-function regulator
(
B+, D+, W, B-) / (B+, L, W, B-, DFM)
Drive end bearing /
Rear bearing dimension
17
X40X12 / 12x28x12
Protection of the Slip rings and
Brushes Compartment
IP 54
Operating (Storage) Temperatures
- 40
°C to + 110°C (+ 130°C)
EMC
Approved (Regulative ECE-R10 Rev.3: 2008-08)
Features
Compact design and small size,
Dust-proof,
CW or CCW rotation fans,
Multi-function regulator with
additional functions (14V),
Pulleys and mounting brackets
available according to customer’s
requirements
Design
3-
phase 6-pole pairs synchronous
generator with integrated rectifier and
voltage regulator,
Double insulated (G2) copper wire
of temperature class over 200°C for
stator and rotor windings,
Rectifier with power press-fit
type Zener diodes with operating
temperature Tj=215°C max,
Mono-Function Regulator (14V, 28V):
Self-Excitation Supply (D+, diode trio),
Microelectronic,
Multi-Function Regulator (14V):
Direct Excitation Supply (B+),
Microelectronic,
Metal-graphite brushes and smaller
diameter copper slip rings for higher
brushes life,
Two internal fans for CW or CCW
rotation,
Special roller type sealed bearings.
Options
Insulated ground (return).
Marine versions available.
1
without pulley
Applications
Applications with higher electrical
requirements and limited mounting space
such as:
Small tractors,
Small agricultural and construction
machinery,
Gen-sets,
Small passenger cars,
Special design for racing cars.
High specific output power,
Over-voltage protection,
Higher protection against accidental
contact,
Lower noise level,
Long life operation,
EMC approved and certified.